Mobile DR YSX-mDR50Y Mobile DR x ray
Model: HXDR-50Y
1. Flat Panel Detector
(1) Type of the detector: TFT monolithic amorphous silicon
(2) Panel size of the detector: 430mm*430mm
(3) Efficient imaging size of the detector: 17*17 inch
(4) Acquisition pixel matrix of the detector: ≥3072×3072
(5) Pixel pitch of the detector: ≤146 um
(6) Spatial resolution of the detector: 3.4LP/MM
(7) Pixel gray scale: 17 Bit
(8) Time of image acquisition and transmission: 3s
2. High frequency and high voltage generator
(1) Max. Output power: 50kw
(2) Input power supply: 220 VAC single phase
(3) Output voltage: 40~150kV
(4) Tube current range: 10~630mA
(5) Exposure time range: 1ms 10000ms
(6) mAs range: 0.1mAs~1000mAs
(7) Support AEC、APR automatic exposure
(8) Diagnostic self test and display
3. X-ray bulb tube assembly
(1) Focus: 0.6mm/1.5mm
(2) Nominal electric power: 21kw/46kw (50Hz)
(3) Max. KV: 150kV
(4) Anode target angle: 12°
4. Column
(1) Rotation angle range of the column is 145°~180°, deviation±2°;(2) Up and down rotation angle of the bulb tube and the beam limiting device on horizontal axis:
90°~45°, deviation±2°;(3) Vertical moving stroke of the X ray tube assembly focus: 95cm, deviation±2cm;(4) Rotation angle in horizontal direction of the bulb tube and the beam limiting device is greater than ±180°;
5. The grid and the beam limiting device
(1) The grid material: Aluminum based grid
(2) Size: 18×18 inch (48×48cm)
(3) Grid ratio: 10:1(4) Wire/inch: 215C
(5) Grid Focal length: 1000mm
Model: YSX-mDR50Y
(6) Light field, multi blade DR beam limiting device
6. Work station functions for image acquisition, processing and diagnosis
(1) Chinese user interface, standard DICOM3.0 image;(2) Work station functions for image acquisition: adjust or preset window width/ window level, local automatic window level, preset window width/ window level, positive and negative image flipping, image flipping, rotation, image magnification and roam, image interpolation edge enhancement, local magnification, restoration, image annotation, text annotation/number annotation, image marking, ruler line segment measurement, square and round measurement, arbitrary shape measurement, angle measurement, automatic electron shearing, image stitching, acquisition and display of exposure index.
(3) Software package for the special image acquisition control and software package for special parts protocol processing;(4) Functions of patient management, image acquisition, image processing (image correction, image flipping, USM sharpening, image filtering), image observation (provide the tools for observation and measurement), image stitching;(5) Image printing, DICOM printing, paper printing, manual printing for the displayed images, single button for marking and printing the images, optional for different printer, film format, and number of prints, print queue control, stop/start the preset;(6) User personalization: showing the format and layout, default setting, toolbar setting, parts protocol enhancement filter;(7) Image display: display configuration 1920×1080, HD display.
7. Work station
(1) CPU: Intel i7,3GHz or above;(2) Host memory: ≥8GB DDR3 1600 high speed memory;(3) Hard disk: 1T/7200rpm large capacity and high speed hard disk;(4) Work station monitor: 24”IPS LCD monitor;(5) Network card and network interface: 1000M network card, 1000M network interface, Jumbo Frames: 9K;
(6) DICOM3.0 interface;(7) Windows 10 64 bit SP1 (Professional Edition or higher).
Configuration list:
No. Parts Name
Qty.
Unit
Notes
1 High voltage generator
1
set
2 X ray tube assembly
1
pc
3 Flat panel detector
1
suit
4 Hanging stand
1
pc
5 Image work station
1
suit
6 Acquisition software
1
suit
7 Beam limiting stitching
1
pc
8
Grid
1
pc
9 High voltage cable
2
pc